6296
Enclosed Conventional Heat Detector, Weatherproof IP67, 72°C, Class BS
- State of the art detector for highest safety
- Waterproof (IP67) for outdoor use or in humid areas
- High temperature range for difficult environments
- Fixed temperature alarm level
Related products
At a glance
General
Heat detectors are normally used in rooms where the temperature can be expected to rise rapidly in case of a fire, or in places where smoke detectors cannot be used. The 6000 series heat detectors are intended for outdoor or indoor use in high humidity areas.
Fixed Temperature Alarm Level
The 6000 series detectors are conventional fixed temperature heat detectors, i.e. they will give an alarm within a response temperature range in accordance with EN54-5. The sensing element is a heat pick-up shield and a bimetal switch. An LED on the detector lights up when the detector activates. All detectors support an output for a remote indicator.
The following types are available (static response temperature, class & EN54-5 temperature range):
• 6295, 57°C, class A2 S (54 to 70°C)
• 6296, 72°C, class B S (69 to 85°C)
• 6297, 87°C, class C S (84 to 100°C)
• 6298, 117°C, class E S (114 to 130°C)
The following types are available (static response temperature, class & EN54-5 temperature range):
• 6295, 57°C, class A2 S (54 to 70°C)
• 6296, 72°C, class B S (69 to 85°C)
• 6297, 87°C, class C S (84 to 100°C)
• 6298, 117°C, class E S (114 to 130°C)
Operation
All detectors are latching, i.e. they will not be automatically reset if the temperature, after the alarm, falls below the detector's static response temperature. The detector's LED and a connected remote LED will be lit until the detector is reset via the C.I.E.
Installation
All electronic componets are mounted in a grey waterproof detector housing and fitted to the supplied connection box. The connection box has three cable inlets. Three compression glands and a silicon gasket for IP67 protection are supplied with the product.
All detectors are provided with three pairs of flying leads with female push-on connectors to connect the zone line cables (in / out) and the remote indicator.
All detectors are provided with three pairs of flying leads with female push-on connectors to connect the zone line cables (in / out) and the remote indicator.
Details
- State of the art detector for highest safety
- Waterproof (IP67) for outdoor use or in humid areas
- High temperature range for difficult environments
- Fixed temperature alarm level
Technical specifications
| General | ||
|---|---|---|
| Status indication |
LED
|
|
| Compatibility |
Conventional systems
|
|
| Alarm levels |
1
|
|
| Connectivity |
2-wire zone
|
|
| Electrical | ||
|---|---|---|
| Power supply type |
Zone powered
|
|
| Operating voltage |
12 to 30 VDC (24 VDC nom.)
|
|
| Current consumption |
0 mA (Quiescent)
6 to 40 mA (±400 Ω) (Alarm, Internal Resistance)
|
|
| No. of cable cores |
2
|
|
| Detection | ||
|---|---|---|
| Detection principle |
Bi-metal plate
|
|
| Zone length |
Controller specific
|
|
| Static response temperature | 72°C | |
| Output | ||
|---|---|---|
| Output quantity |
1
|
|
| Output type and rating |
Remote indicator, < 10 mA @ Supply - 2 VDC
|
|
| Physical | ||
|---|---|---|
| Physical dimensions |
100 x 75 mm (Ø x D)
|
|
| Net weight |
133 g
|
|
| Colour |
Grey
|
|
| Mounting type |
Base mount
|
|
| Cable entries |
2
|
|
| Material (body) |
Modified polycarbonate
|
|
| Environmental | ||
|---|---|---|
| Vandal proof |
No
|
|
| Operating temperature |
-40 10 110°C
|
|
| Storage temperature |
-45 to +70°C
|
|
| Relative humidity |
< 95%
|
|
| Environment |
Indoor
Outdoor
|
|
| IP rating |
IP67
|
|
| Regulatory | ||
|---|---|---|
| Compliancy |
CE
REACH
RoHS 3
WEEE
|
|
| Certification |
CPR
|
|
| Voluntary marks |
VdS
|
|
| Standards |
EN54-5
|
|
Downloads
All downloadsDatasheet
Certificates
CPD / CPR
If available, the downloads of the Certificates, Software & Firmware and Media are displayed in their default language.